There are 3 types of electrolysis used for permanent hair removal: galvanic, thermolysis, and blend. Each type uses a different form of electrical energy to destroy the hair follicle, and each produces different levels of follicular destruction. The type of electrolysis used during treatment directly affects the permanence, comfort, and consistency of results.
Not all electrolysis is the same. The method your electrologist uses — called the modality — determines how the hair follicle is destroyed and whether that destruction is complete enough to prevent regrowth. The delivery system (single-probe or multiprobe) adds another layer of difference that affects treatment speed and thoroughness.
This page compares all 3 types of electrolysis, explains the practical differences between them, and outlines what to look for when choosing a clinic — so you can make an informed decision about which method is right for your hair removal goals.
The 3 Types of Electrolysis at a Glance
Each type of electrolysis targets the hair follicle using electrical current, but the form of energy, the mechanism of destruction, and the delivery system differ across all 3 methods.
| Galvanic | Thermolysis | Blend |
Energy Type | Chemical (direct current) | Heat (alternating current) | Chemical + heat |
What It Produces | Sodium hydroxide (NaOH) | Thermal coagulation | Heated sodium hydroxide |
Destruction Target | Entire follicle inc. bulge | Lower follicle primarily | Broader than thermolysis |
Probe System | Single or multiprobe | Single-probe only | Single-probe only |
Speed Per Hair | Moderate (single) / Fast (multi) | Fastest per individual hair | Moderate |
Retreatment Rate | Lowest | Highest | Moderate |
Comfort | Mild tingling, no heat | Heat sensation, can sting | Mild heat |
Skin Irritation Risk | Minimal | Higher (surface heat) | Moderate |
The following sections explain each method in practical terms — what happens during treatment, how complete the destruction is, and what that means for your results.
Galvanic Electrolysis — Chemical Destruction
Galvanic electrolysis uses direct current (DC) delivered through a fine sterile probe into the hair follicle. The current reacts with the water (H₂O) and dissolved salt (NaCl) naturally present inside the follicle, producing sodium hydroxide (NaOH) — a strong alkaline compound that chemically dissolves the follicle’s growth structures.
Sodium hydroxide is a liquid. Once formed, it disperses throughout the entire follicle cavity, reaching and destroying 3 structures: the dermal papilla, the germinal matrix, and the bulge stem cell region. This complete distribution is why galvanic electrolysis achieves the most thorough form of follicular destruction of all 3 methods.
Galvanic electrolysis is the only type that can be performed using a multiprobe system — where multiple sterile probes are inserted into multiple follicles simultaneously. The current is delivered to all targeted follicles at the same time, making multiprobe galvanic the fastest method for clearing dense treatment areas such as the chin, jawline, and upper lip.
There is no heat applied to the skin during galvanic electrolysis. The destruction is entirely chemical. The sensation during treatment is a mild tingling.
Galvanic electrolysis was first used for hair removal in 1875 and remains the most clinically proven method of permanent hair removal after more than 140 years of documented use.
Thermolysis — Heat-Based Destruction
Thermolysis uses high-frequency alternating current (AC) to generate heat inside the hair follicle. The heat causes rapid vibration of water molecules in the surrounding tissue, which coagulates and destroys the growth cells through thermal action. This process is called targeted cellular ablation.
Thermolysis acts fast. Each hair can be treated in a fraction of a second, which is why thermolysis is often called ‘flash electrolysis.’ It is a single-probe method — 1 follicle is treated at a time.
There are 3 practical limitations with thermolysis:
- Incomplete follicle coverage — the heat is concentrated in the lower portion of the follicle. The bulge stem cell region, located higher in the follicle wall, may survive treatment. When the bulge survives, the follicle can regenerate, and regrowth occurs.
- Higher retreatment rate — because destruction may not be complete on the first pass, the same follicle often requires multiple treatments before it is permanently disabled. This increases total session count and overall treatment time.
- Surface skin irritation — the heat generated during thermolysis can cause temporary redness, swelling, or irritation at the skin surface, particularly in sensitive treatment areas such as the upper lip and chin.
Thermolysis is best suited for treating fine, shallow hair in areas where speed per individual hair is prioritised over thoroughness of destruction. It is not available in multiprobe format.
Blend Electrolysis — Combined Approach
Blend electrolysis combines galvanic direct current with thermolysis alternating current, delivered through a single probe into the hair follicle. The galvanic component produces sodium hydroxide inside the follicle, while the thermolysis component heats the chemical reaction, accelerating the rate at which sodium hydroxide denatures the follicle’s proteins.
The blend method was developed to address the limitations of thermolysis by adding the chemical action of galvanic current. The result is more thorough destruction than thermolysis alone, particularly for resistant, distorted, or deeply embedded follicles.
There are 2 practical limitations with blend electrolysis:
- Single-probe only — blend cannot be delivered through a multiprobe system. Treatment speed is limited to 1 follicle at a time, making it slower than multiprobe galvanic for clearing dense areas.
- Heat exposure — because blend includes a thermolysis component, clients are still exposed to heat during treatment. The level of heat is lower than pure thermolysis, but the sensation is present.
Blend requires a high level of technical skill from the electrologist to balance the galvanic and thermolysis current settings for each follicle type. Clinical studies have not demonstrated a measurable difference in long-term effectiveness between blend and pure galvanic electrolysis.
Which Type of Electrolysis Delivers the Best Results?
Galvanic electrolysis produces the most complete follicular destruction of all 3 methods. The sodium hydroxide it generates disperses throughout the entire follicle — reaching the dermal papilla, germinal matrix, and bulge stem cell region. This is why galvanic has the lowest retreatment rate per follicle and delivers the most consistent permanent results.
When galvanic is delivered through a multiprobe system, it becomes the fastest method in practice for clearing dense treatment areas. A multiprobe galvanic system treating 16 follicles simultaneously clears more hair per hour than single-probe thermolysis, despite thermolysis being faster on a per-hair basis.
The choice of electrolysis type matters most in 4 situations:
- Coarse or deep-rooted hair — galvanic achieves full-depth destruction. Thermolysis may not reach the base of deeper follicles.
- Hormonally influenced hair (polycystic ovary syndrome (PCOS), menopause, hormone therapy) — these follicles are often thicker, distorted, and resistant to heat-based methods. Galvanic sodium hydroxide dissolves them completely.
- Dense treatment areas (chin, jawline, upper lip) — multiprobe galvanic clears these areas faster and more consistently than single-probe methods.
- Clients who have experienced regrowth after previous electrolysis — regrowth after thermolysis or blend often indicates the bulge region was not destroyed. Galvanic electrolysis targets and destroys the bulge.
For fine, shallow hair in less dense areas, thermolysis can be effective. For comprehensive, permanent results across all hair types and treatment areas, galvanic multiprobe electrolysis delivers the highest standard of outcome.
How to Know Which Type Your Clinic Uses
Many clinics describe their service as ‘electrolysis’ without specifying the type. The term ‘electrolysis’ is used as an umbrella for all 3 methods, which can make it difficult to know what you are receiving.
There are 4 questions to ask any electrolysis provider before starting treatment:
- Which type of electrolysis do you use — galvanic, thermolysis, or blend? The answer tells you the mechanism of destruction.
- Do you use a single-probe or multiprobe system? Only galvanic offers multiprobe capability.
- How do you determine the current settings and duration for each follicle? A qualified electrologist adjusts these based on follicle depth, hair type, and probe size.
- Do you provide a hair density assessment before creating a treatment plan? A structured plan based on measured hair density produces better results than session-by-session treatment without a defined program.
The answers to these 4 questions reveal the level of precision, expertise, and technology behind the treatment you will receive.
Frequently Asked Questions
What are the 3 types of electrolysis?
The 3 types of electrolysis are galvanic, thermolysis, and blend. Galvanic uses direct current to produce sodium hydroxide that chemically destroys the follicle. Thermolysis uses alternating current to generate heat that coagulates the growth cells. Blend combines both galvanic and thermolysis currents in a single treatment. All 3 are classified under ‘electrolysis,’ but each uses a different mechanism and produces different levels of follicular destruction
Which type of electrolysis is the most effective?
Galvanic electrolysis produces the most thorough follicular destruction. The sodium hydroxide it generates disperses throughout the entire follicle, destroying the dermal papilla, germinal matrix, and bulge stem cell region. Galvanic has the lowest retreatment rate per follicle and, when delivered via multiprobe, is the fastest method for clearing dense treatment areas.